Images Stopped Syncing: New X-rays Not Appearing in Second Opinion

Troubleshoot missing X-rays in Second Opinion, whether the problem affects one patient or your whole office.

Start here: how many images are missing?

  • No new X-rays for anyone (for example, "nothing since Friday" or "today's patients aren't there"): follow Part A.
  • Only one operatory, one image type or one patient: follow Part B.
  • Every office and workstation at once, very suddenly: it may be a Pearl service issue. See Is Second Opinion Down?

How quickly images normally appear

  • X-rays taken today appear within a few minutes.
  • Back-dated or imported X-rays (study date in the past) are processed overnight and appear the next morning.
  • After a connection is fixed, missed images fill in over the next several hours, usually within 24 hours.

Part A: No new X-rays for anyone

Pearl's software runs on the server or computer that stores your X-rays, not on each workstation. Most sync problems start there.

  1. Check the imaging software. Do the new X-rays show in your imaging software, saved to the right patient? If not, the problem is in the imaging software. Contact your imaging vendor or IT.
  2. Note when it stopped. Find the date and time of the last image that did appear in Second Opinion.
  3. Think about what changed around then: a new or rebuilt server; a Windows, PMS or imaging update or upgrade; a power or internet outage; new antivirus or security software; a changed database password; IT work on the network. If you replaced the server or changed your PMS or imaging system, see Moving to a New Server or Changing Your PMS or Imaging System. The Pearl software must be reinstalled or reconfigured.
  4. Check the server. Is it switched on and connected to the internet? Is the drive where images are stored or Pearl runs full?
  5. Check the Pearl services (or ask IT to). On the server, open Services (services.msc). Look for Pearl Image Upload Agent and, if you use Pearl products that read your PMS, Pearl PMS Sync Agent. If either is stopped, start it. Don't stop them otherwise.
  6. Check security software. Ask IT to exclude C:\Program Files\Pearl\piusvc.exe in antivirus or EDR, and to allow Pearl's web addresses (see Network, Firewall and Antivirus Settings for Pearl).
  7. Eaglesoft native offices: check that the Patterson Image Server service is running on the Eaglesoft server, then take a test X-ray.
  8. Cloud or vendor-connected systems (Curve, Sota Cloud, Open Dental native, XVWeb/Denticon, DS Core): your vendor sends images to Pearl. If images are missing there too, contact the vendor. For DS Core, check that the DS Core or Sidexis connector service is running.
  9. Wait about an hour after a restart or network fix. If new X-rays still don't appear, contact support.

Part B: Only some images are missing

  • One operatory or capture PC: that computer probably isn't saving images where Pearl looks for them. Contact support; a remote session on that PC may be needed.
  • Only panoramics, or only one sensor: a new pano unit, sensor or capture station may save to a different folder. Contact support so Pearl can add it for compatible systems.
  • One patient:
    1. Search by patient name, patient ID or X-ray date on the home screen.
    2. Use the image-date dropdown on the patient.
    3. Look under Unclassified and in stacks (a blue circle with a number).
    4. Check whether the images are on another patient (see How to Move Images).
    5. In TigerView and some other systems, the image must have a PMS patient ID; add it in the imaging software and the images sync.
    6. For names showing "NA", see Patient Name Shows NA.
  • Some images from a study (for example 2 of 4 bitewings): the AI may not have recognized them as supported X-rays. Retake if needed, or tell support how many are missing.
  • Older X-rays: only X-rays within your included history window are imported (see Missing Images). Second Opinion has no manual upload; images must come from your imaging system.

When to contact support, and what to include

Submit a support request (or use the chat) with:

  • your PMS and imaging software
  • whether all patients and workstations are affected
  • the date the last image appeared
  • any recent change
  • your IT contact and a time when someone can open a remote session on the server
  • for a specific patient: the PMS patient ID, study date and image type