Images Stopped Syncing: New X-rays Not Appearing in Second Opinion
Troubleshoot missing X-rays in Second Opinion, whether the problem affects one patient or your whole office.
Start here: how many images are missing?
- No new X-rays for anyone (for example, "nothing since Friday" or "today's patients aren't there"): follow Part A.
- Only one operatory, one image type or one patient: follow Part B.
- Every office and workstation at once, very suddenly: it may be a Pearl service issue. See Is Second Opinion Down?
How quickly images normally appear
- X-rays taken today appear within a few minutes.
- Back-dated or imported X-rays (study date in the past) are processed overnight and appear the next morning.
- After a connection is fixed, missed images fill in over the next several hours, usually within 24 hours.
Part A: No new X-rays for anyone
Pearl's software runs on the server or computer that stores your X-rays, not on each workstation. Most sync problems start there.
- Check the imaging software. Do the new X-rays show in your imaging software, saved to the right patient? If not, the problem is in the imaging software. Contact your imaging vendor or IT.
- Note when it stopped. Find the date and time of the last image that did appear in Second Opinion.
- Think about what changed around then: a new or rebuilt server; a Windows, PMS or imaging update or upgrade; a power or internet outage; new antivirus or security software; a changed database password; IT work on the network. If you replaced the server or changed your PMS or imaging system, see Moving to a New Server or Changing Your PMS or Imaging System. The Pearl software must be reinstalled or reconfigured.
- Check the server. Is it switched on and connected to the internet? Is the drive where images are stored or Pearl runs full?
- Check the Pearl services (or ask IT to). On the server, open Services (
services.msc). Look for Pearl Image Upload Agent and, if you use Pearl products that read your PMS, Pearl PMS Sync Agent. If either is stopped, start it. Don't stop them otherwise. - Check security software. Ask IT to exclude
C:\Program Files\Pearl\piusvc.exein antivirus or EDR, and to allow Pearl's web addresses (see Network, Firewall and Antivirus Settings for Pearl). - Eaglesoft native offices: check that the Patterson Image Server service is running on the Eaglesoft server, then take a test X-ray.
- Cloud or vendor-connected systems (Curve, Sota Cloud, Open Dental native, XVWeb/Denticon, DS Core): your vendor sends images to Pearl. If images are missing there too, contact the vendor. For DS Core, check that the DS Core or Sidexis connector service is running.
- Wait about an hour after a restart or network fix. If new X-rays still don't appear, contact support.
Part B: Only some images are missing
- One operatory or capture PC: that computer probably isn't saving images where Pearl looks for them. Contact support; a remote session on that PC may be needed.
- Only panoramics, or only one sensor: a new pano unit, sensor or capture station may save to a different folder. Contact support so Pearl can add it for compatible systems.
- One patient:
- Search by patient name, patient ID or X-ray date on the home screen.
- Use the image-date dropdown on the patient.
- Look under Unclassified and in stacks (a blue circle with a number).
- Check whether the images are on another patient (see How to Move Images).
- In TigerView and some other systems, the image must have a PMS patient ID; add it in the imaging software and the images sync.
- For names showing "NA", see Patient Name Shows NA.
- Some images from a study (for example 2 of 4 bitewings): the AI may not have recognized them as supported X-rays. Retake if needed, or tell support how many are missing.
- Older X-rays: only X-rays within your included history window are imported (see Missing Images). Second Opinion has no manual upload; images must come from your imaging system.
When to contact support, and what to include
Submit a support request (or use the chat) with:
- your PMS and imaging software
- whether all patients and workstations are affected
- the date the last image appeared
- any recent change
- your IT contact and a time when someone can open a remote session on the server
- for a specific patient: the PMS patient ID, study date and image type